OVERVIEW

Lantech IPES-5408DFTis a high performance L2+ (Gigabit uplink) Ethernet switch with 8 10/100TX+2 10/100/1000T+2Dual Speed 100/1000M SFP w/8 PoE 802.3af/at ports with total PoE budget 120W which provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms covering multi-cast and data packets, comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, SSH v2/SSL, TACACS+**; Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ (double tagVLAN) which are important features required in train and large network. It also supports Cisco Discovery Protocol (CDP) and LLDP for Ciscoworks to detect the switch info and show on L2 map topology.

 

Up to 8 PoEat/af ports w/advanced PoE management

Compliant with 802.3af/at standard, the Lantech IPES-5408DFT is able to feed each PoE port up to 30 Watt, total PoE budget 120W. Lantech IPES-5408DFT supports advanced PoE management including PoE detection and scheduling. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Each PoE port can be Enabled/disabled, get the voltage, current, Watt, and temperature info displayed on WebUI.

 

Miss-wiring avoidance, Loop protection, Node Failure protection

The IPES-5408DFT also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPES-5408DFT is able to alert with the LED indicator and send out an email or traps. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMSwhen each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.

 

Enhanced G.8032 Ring < 20ms for single ring recovery; auto ring, double ring,multi-chain covering multicast packets; MSTP with 16 MSTI

Lantech IPES-5408DFT features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring by easy setup than others.  The innovative node failure protection can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over VLAN for redundant links with 8 MSTI. The ITU G.8032 Ring and RSTP can beco-existed in the same switch with different ports for the most flexible protection.

 

DHCP option 82 & port based, Mac based DHCP, Option66, DHCP Snooping, IPv6 DHCP server

DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch), it also can assign IP address by port for multiple switches with single DHCP option82 server. DHCP Snooping is supported. For the ending device which need to download file from TFTP server, DHCP Option66 server can offer IP address of TFTP server to DHCP client. Basic IPv6 DHCP service can be supported.

 

QoS by VLANfor legacy devices

QoS by VLAN can allow switch to tag (C-tag and S-tag) QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the band width management in a network.

 

QinQ, QoS andGVRP supported

It supports the QinQ, QoS and GVRP for large VLAN segmentation.

 

IGMPv3, GMRP,router port, MLD Snooping, static multicast forwarding and multicast Ringprotection
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP, router port, MLD snooping and static multicast forwarding binding by ports for video surveillance application.

 

802.1X security by MAC address

MAC-based port authentication is an alternative approach to 802.1x for authenticating hosts connected to a port. By authenticating based on the host's source MAC address, the host is not required to run a user for the 802.1x protocol. The RADIUS server that performs the authentication will inform the switch if this MAC can be registered in the MAC address table of switch.

 

Auto-provisioning for firmware/configuration update

The switch supports auto-provisioning for switch to auto-check the latest software image and configuration through TFTP server.

 

Auto topology drawing, User friendly UI, Complete CLI, DMI with dB value***

The user friendly UI, innovative auto topology drawing and topology demo makes IPES-5408DFT much easier to get hands-on. The switch also equips the RTC (real time clock)which can keep track of time always. The IPES-5408DFT supports DMI interface that can correspond with DDM SFPs (Digital diagnostic monitor) to display the five parameters in Lantech’s UI, including optical output power, input power,temperature, laser bias current and transceiver supply voltage***. The TX power/RX power raw data is automatically converted to dB values for installer,making it easier to calculate the fiber distance. The complete CLI enables professional engineer to configure setting by command line.

 

Exported configuration text file; Factory reset button; CPU watchdog; Built-in RTC

The configuration file of Lantech IPES-5408DFT can be exported in text file so thatit can be edited and configured back to switch with ease for mass deployment.The factory reset button can restore the setting back to factory default and built-in watchdog design can automatically reboot the switch when CPU is found dead.

 

USB port& N-key** for back up, restore configuration and upgrade firmware

The built-in USB port can upload/download the firmware through USB dongle for switch replacement

 With optional N-key**, the configuration file can be mass auto backup, editable restored and auto upgrade firmware for easy maintenance.

 

2DI / 2DOrelay to alarm and email/trap

The IPES-5408DFT DIDO function can support additional open/close physical contact for designate applications besides Port / Power events, for example, DIDO function can trigger alarm if the switch was moved or stolen. In case of events, the IPES-5408DFT will immediately send an email message to pre-defined addresses as well as SNMP Traps out. It provides 2DI and 2DO while disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.

 

Optional environmental monitoring** for switch inside information (-M model)

The environmental monitoring can detect switch overall temperature, voltage, totalPoE load and current where can send the SNMP traps and email when abnormal.

 

DC powered input; Relay contact alarm

The Lantech IPES-5408DFT is designed with ±48VDC power input ranges from ±44V~±56VDC. Optional 12V model can accept power input from 9.5V~56VDC. Featured with relay contact alarm function, the IPES-5408DFT is able to connect with alarm system in case of power failure or port disconnection. The IPES-5408DFT also provides ±2000V EFT and±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet.

 

High reliability and extended working temperature

Lantech IPES-5408DFT features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory,substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul,Semi-conductor factory and assembly lines.

 

Can be used in extreme environments with an operating temperature range of -40°C to 75°C.

*Future Release
**Optional
***Optional DDM SFP required

SPECIFICATIONS

Hardware Specifications

||| | --- | --- | |

Standards

| [cite_start]

IEEE802.3 10Base-T Ethernet, IEEE802.3u 100Base-TX, IEEE802.3ab 1000Base-T Ethernet, IEEE802.3z Gigabit fiber, IEEE802.3x Flow Control and Back Pressure, IEEE802.3ad Port trunk with LACP, IEEE802.1d Spanning Tree, IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree, IEEE802.3ad Link Aggregation Control Protocol (LACP), IEEE802.1AB Link Layer Discovery Protocol (LLDP), IEEE802.1X User Authentication (Radius), IEEE802.1p Class of Service, IEEE802.1Q VLAN Tag, IEEE802.3at/af Power over Ethernet [cite: 1]

| |

Switch Architecture

| [cite_start]

Back-plane (Switching Fabric): 9.6Gbps [cite: 1]

| |

Transfer Rate

| [cite_start]

14,880pps for Ethernet port, 148,800pps for Fast Ethernet port, 1,488,000pps for Gigabit Ethernet / Gigabit Fiber port [cite: 1]

| |

Mac Address

| [cite_start]

16K MAC address table [cite: 1]

| |

Jumbo frame

| [cite_start]

10KB [cite: 1]

| |

Connectors

| [cite_start]

10/100TX: 8 x ports RJ-45 with Auto MDI/MDI-X function, 10/100/1000T: 2 x ports RJ-45 with Auto MDI/MDI-X function, Mini-GBIC: 2 x Dual Speed 100/1000M SFP socket with DDM, RS-232 connector: RJ-45 type, Power & Relay connector: 1 x 6-pole terminal block, DIDO : 1 x 6-pole terminal block [cite: 1]

| |

Network Cable

|

10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable, EIA/TIA-568 100-ohm (100m); 100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable, EIA/TIA-568 100-ohm (100m); 1000Base-TX: 2-pair UTP/STP Cat. [cite_start]5/ 5E/ 6 cable, EIA/TIA-568 100-ohm (100m) [cite: 1]

| |

Optical Cable

|

1.25Gbps: Multi mode (850nm/1310nm), Single mode (1310nm/1550nm); 125Mbps: Multi mode (1310nm), Single mode (1310nm); WDM 1.25Gbps: Single mode (1310nm/1490nm/1550nm); [cite_start]WDM 125Mbps: Single mode (1310nm/1550nm) [cite: 1]

| |

LED

|

Per unit: Power 1 (Green), Power 2 (Green), FAULT (Red), RM(Green); Ethernet port: Link/Activity (Green); Mini-GBIC: Link/Activity (Green); [cite_start]PoE: Active (Green) [cite: 1]

| |

DI/DO

|

2 Digital Input (DI): Level 0: -30~2V / Level 1: 10~30V (Max. input current: 8mA); [cite_start]2 Digital Output (DO): Open collector to 40 VDC, 200mA [cite: 1]

| |

Operating Humidity

| [cite_start]

5% ~ 95% (Non-condensing) [cite: 1]

| |

Operating Temperature

| [cite_start]

-20°C~60°C / -4°F~140°F (Standard model), -40°C~75°C / -40°F~167°F (-E model) [cite: 1]

| |

Storage Temperature

| [cite_start]

-40°C~85°C / -40°F~185°F [cite: 1]

| |

Power Input

|

48V model: ±44 ~ ±56VDC; [cite_start]12V model: 9.5~56VDC [cite: 1]

| |

PoE Budget

|

Max. [cite_start]120W (50-56VDC input is recommended for 802.3at 30W applications), Higher PoE budget can be applied upon request [cite: 1]

| |

PoE pin assignment

|

RJ-45 port # 1~ # 8 support IEEE 802.3at/af End-point. Per port provides up to 30W; Positive (VCC+): RJ-45 pin 1,2; [cite_start]Negative (VCC-): RJ-45 pin 3,6 [cite: 1]

| |

Case Dimension

|

Metal case. [cite_start]IP-30, 74 (W) x 135 (D) x 152 (H) mm [cite: 1]

| |

Weight

| [cite_start]

900 g [cite: 1]

| |

Installation

| [cite_start]

DIN Rail and Wall Mount Design [cite: 1]

| |

EMI & EMS

| [cite_start]

FCC Part 15 Class A, EN 55011, EN 61000-6-2, IEC 61000-4-2/3/4/5/6/8, BS EN55032, BS EN55024, BS EN61000-4-2/3/4/5/6/8 [cite: 1]

| |

Stability Testing

| [cite_start]

IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-64 (Vibration) [cite: 1]

| |

Railway compliance

| [cite_start]

EN 50121-4, EN 50121-5 [cite: 1]

| |

Safety

| [cite_start]

IEC/BS EN IEC 62368-1 2020/A11:2020 [cite: 1]

| |

MTBF

|

797,866.5 Hrs. (standards: IEC 62380) [cite_start][cite: 1]

| |

Warranty

| [cite_start]

5 years [cite: 1]

|

Software Specifications

||| | --- | --- | |

Management

| [cite_start]

SNMP v1 v2c, v3/ Web/Telnet/CLI [cite: 1]

| |

SNMP MIB

| [cite_start]

MIB, MIBII, SNMP MIB, Bridge MIB, IF MIB, RMON MIB, Private MIB [cite: 1]

| |

ITU G.8032

| [cite_start]

Support ITU G.8032 v2/2012 for Ring protection in less than 20ms for self-heal recovery (single ring), Support various ring/chain topologies covering multi-cast and data packets, Includes train ring & double ring 12 topologies etc, Enhanced G.8032 ring configuration with ease, Co-exist with RSTP on different ports [cite: 1]

| |

PoE Management

|

PoE Detection to check if PD hangs then restart the PD; PoE configuration; [cite_start]PoE monitoring [cite: 1]

| |

Per Port PoE Status

| [cite_start]

Enable/Disable, voltage, current, watts, temperature [cite: 1]

| |

User friendly UI

| [cite_start]

Auto topology drawing, Topology demo, Auto configuration for G.8032(auto mode) for single ring, DDM threshold monitoring with dB values***, Complete CLI for professional setting [cite: 1]

| |

Port Trunk with LACP

|

LACP Port Trunk: 8 Trunk groups/Maximum 8 trunk members [cite: 1]

| |

LLDP

|

Supports LLDP to allow switch to advise its identification and capability on the LAN [cite: 1]

| |

CDP

|

Cisco Discovery Protocol for topology mapping [cite: 1]

| |

Environmental Monitoring**

| [cite_start]

System status for input voltage, current and ambient temperature to be shown in GUI and sent alerting if any abnormal status (-M model) [cite: 1]

| |

VLAN

| [cite_start]

Port Based VLAN IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096.) GVRP, QinQ, Protocol based VLAN, IPv4 Subnet based VLAN [cite: 1]

| |

RSTP/MSTP

| [cite_start]

Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree, IEEE802.1s Multiple Spanning Tree with 16 MSTI [cite: 1]

| |

Quality of Service

| [cite_start]

The quality of service determined by port / CoS / ToS / VLAN / 61375-3-4 [cite: 1]

| |

Class of Service

| [cite_start]

Support IEEE802.1p class of service, per port provides 8 priority queues [cite: 1]

| |

MLD Snooping

| [cite_start]

Support IPv6 Multicast stream [cite: 1]

| |

Login Security

| [cite_start]

Supports IEEE802.1X Authentication/RADIUS [cite: 1]

| |

Port Mirror

| [cite_start]

Support 3 mirroring types: “RX, TX and Both packet” [cite: 1]

| |

Network Security

| [cite_start]

Support 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder., 802.1X access control for port based and MAC based authentication/MAC-Port binding, Management access control with priority , Ingress/Egress ACL L2/L3, SSL/ SSH v2 for Management, HTTPS for secure access to the web interface, TACACS+** for Authentication, MAC filter [cite: 1]

| |

IGMP

|

Support IGMP snooping v1,v2,v3; Supports IGMP static route; 256 multicast groups; IGMP router port ; IGMP query; [cite_start]GMRP** [cite: 1]

| |

Static MAC-Port bridge

| [cite_start]

Static multicast forwarding forward reversed IGMP flow with multicast packets binding with ports for IP surveillance application [cite: 1]

| |

Bandwidth Control

|

Support ingress packet filter and egress packet limit. The egress rate control supports all of packet type. Ingress filter packet type combination rules are Broadcast/Multicast/Flooded Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all types of packet. [cite_start]The packet filter rate can be set an accurate value through the pull-down menu for the ingress packet filter and the egress packet limit. [cite: 1]

| |

RTC

| [cite_start]

Built-in Real Time Clock to keep track of time always [cite: 1]

| |

Flow Control

| [cite_start]

Supports Flow Control for Full-duplex and Back Pressure for Half-duplex [cite: 1]

| |

System Log

| [cite_start]

Supports System log record and remote system log server(RFC3164) [cite: 1]

| |

Relay Alarm

|

Provides one relay output for port breakdown, power fail and alarm. [cite_start]Alarm Relay current carry ability: 1A @ DC24V [cite: 1]

| |

Protection

| [cite_start]

Miss-wiring avoidance, Node failure protection, Loop protection [cite: 1]

| |

SNMP Trap

| [cite_start]

Up to 10 trap stations; trap types including: Device cold start, Authorization failure, Port link up/link down, DI/DO open/close, Typology change(ITU ring), Power failure, Environmental abnormal** [cite: 1]

| |

DHCP

|

Provide DHCP Client/ DHCP Server/DHCP Option 82/Port based DHCP; DHCP Option 66; [cite_start]DHCP Snooping; basic IPv6 DHCP server [cite: 1]

| |

Mac based DHCP Server

| [cite_start]

Assign IP address by Mac [cite: 1]

| |

DNS

| [cite_start]

Provide DNS client feature [cite: 1]

| |

SNTP

| [cite_start]

Supports Dual NTP server to synchronize system clock in Internet [cite: 1]

| |

Diagnostic

| [cite_start]

Support Ping and DDM information [cite: 1]

| |

Firmware Update

|

Supports TFTP firmware update, TFTP backup and restore; [cite_start]HTTP firmware upgrade [cite: 1]

| |

Configuration backup & restore

| [cite_start]

Supports text configuration file for system quick installation, N-key** for mass firmware auto-backup, editable restoration and auto upgrade, USB port to upload/download firmware by USB dongle [cite: 1]

| |

Auto Provision

| [cite_start]

To verify switch firmware with the latest or certain version [cite: 1]

|
*Future Release
**Optional
***Optional DDM SFP required
No items found.

ORDERING INFORMATION

| P/N | Model name | Description | | --- | --- | --- | | 8350-53841 | IPES-5408DFT | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, ±44 ~ ±56VDC input; -20°C to 60°C | | 8350-53851 | IPES-5408DFT-E | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, ±44 ~ ±56VDC input; -40°C to 75°C | | 8350-53861 | IPES-5408DFT-12V | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, dual 9.5~56VDC input; -20°C to 60°C | | 8350-53871 | IPES-5408DFT-12V-E | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, dual 9.5~56VDC input; -40°C to 75°C | | 8350-5384 | IPES-5408DFT-M | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, ±44 ~ ±56VDC input; w/ Environmental monitoring; -20°C to 60°C | | 8350-5385 | IPES-5408DFT-M-E | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, ±44 ~ ±56VDC input; w/ Environmental monitoring; -40°C to 75°C | | 8350-5386 | IPES-5408DFT-M-12V | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, dual 9.5~56VDC input; w/ Environmental monitoring; -20°C to 60°C | | 8350-5387 | IPES-5408DFT-M-12V-E | 2 10/100/1000T + 2 Dual Speed 100/1000M SFP + 8 10/100TX w/8 PoE at/af up to 30W L2+ Industrial Managed Ethernet Switch w/USB slot, dual 9.5~56VDC input; w/ Environmental monitoring; -40°C to 75°C |

OPTIONAL ACCESSORIES - DIN Rail Power

| Model name | Description | | --- | --- | | NDR-480 Series | 480W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) | | NDR-240 Series | 240W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) | | NDR-120 Series | 120W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet) | | NDR-75 Series | 75W Single Output Industrial Din Rail Power; 90-264VAC / 127-370VDC Input Range; Cooling by free air convection; RoHS2 ; Operating Temp. -20°C~70°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C; For 115VAC, please refer to derating curve on NDR-120 Series datasheet) |

OPTIONAL ACCESSORIES - Mini GBIC (SFP)

| Model name | Description | Model name | Description | | --- | --- | --- | --- | | 8330-162D-V1 | MINI GBIC 1000SX | (LC/MM/0.5KM) Transceiver | | 8330-163D-V1 | MINI GBIC 1000SX2 | (LC/MM/2KM) Transceiver | | 8330-165D-V1 | MINI GBIC 1000LX | (LC/SM/10KM) Transceiver | | 8340-0591D-V1 | MINI GBIC 1000LHX | (LC/SM/40KM) Transceiver | | 8330-166D-V1 | MINI GBIC 1000XD | (LC/SM/50KM) Transceiver | | 8330-169D-V1 | MINI GBIC 1000XD | (LC/SM/60KM) Transceiver | | 8330-167D-V1 | MINI GBIC 1000ZX | (LC/SM/80KM) Transceiver | | 8330-170D-V1 | MINI GBIC 1000EZX | (LC/SM/120KM) Transceiver | | 8330-168-V1 | MINI GBIC 10/100/1000T | (100m) Transceiver | | 8330-060D-V1 | MINI GBIC 100Base | (LC/MM/2KM) Transceiver | | 8330-065D-V1 | MINI GBIC 100Base | (LC/MM/5KM) Transceiver | | 8330-061D-V1 | MINI GBIC 100Base | (LC/SM/30KM) Transceiver | | 8330-197D-V1 | 1.25Gbps BiDi SFP | 0.5KM Transceiver (WDM 1310) | | 8330-198D-V1 | 1.25Gbps BiDi SFP | 0.5KM Transceiver (WDM 1550) | | 8330-195D-V1 | 1.25Gbps BiDi SFP | 2KM Transceiver (WDM 1310) | | 8330-196D-V1 | 1.25Gbps BiDi SFP | 2KM Transceiver (WDM 1550) | | 8330-188D-V1 | 1.25Gbps BiDi SFP | 10KM Transceiver (WDM 1310) | | 8330-189D-V1 | 1.25Gbps BiDi SFP | 10KM Transceiver (WDM 1550) | | 8330-186D-V1 | 1.25Gbps BiDi SFP | 20KM Transceiver (WDM 1310) | | 8330-187D-V1 | 1.25Gbps BiDi SFP | 20KM Transceiver (WDM 1550) | | 8330-180D-V1 | 1.25Gbps BiDi SFP | 40KM Transceiver (WDM 1310) | | 8330-182D-V1 | 1.25Gbps BiDi SFP | 40KM Transceiver (WDM 1550) | | 8330-181D-V1 | 1.25Gbps BiDi SFP | 60KM Transceiver (WDM 1310) | | 8330-183D-V1 | 1.25Gbps BiDi SFP | 60KM Transceiver (WDM 1550) | | 8330-184D-V1 | 1.25Gbps BiDi SFP | 80KM Transceiver (WDM 1490) | | 8330-185D-V1 | 1.25Gbps BiDi SFP | 80KM Transceiver (WDM 1550) | | 8330-071D-V1 | 125Mbps BiDi SFP | 2KM (WDM 1310) Transceiver | | 8330-072D-V1 | 125Mbps BiDi SFP | 2KM (WDM 1550) Transceiver | | 8330-069D-V1 | 125Mbps BiDi SFP | 20KM (WDM 1310) Transceiver | | 8330-068D-V1 | 125Mbps BiDi SFP | 20KM (WDM 1550) Transceiver | | 8330-080D-V1 | 125Mbps BiDi SFP | 40KM (WDM 1310) Transceiver | | 8330-082D-V1 | 125Mbps BiDi SFP | 40KM (WDM 1550) Transceiver | | 8330-081D-V1 | 125Mbps BiDi SFP | 60KM (WDM 1310) Transceiver | | 8330-083D-V1 | 125Mbps BiDi SFP | 60KM (WDM 1550) Transceiver | | 8330-084D-V1 | 125Mbps BiDi SFP | 80KM (WDM 1310) Transceiver | | 8330-085D-V1 | 125Mbps BiDi SFP | 80KM (WDM 1550) Transceiver | | 8330-191D-V1 | Dual Speed SFP | 100M/1000M-LX 10KM Transceiver | | | | All SFP P/N# ended with D are with DDM function | |

OPTIONAL ACCESSORIES - Wall Mount Bracket

| Model name | Description | | --- | --- | | MBAK19003 | Wall mount bracket for 74(W) x 105 (D) x 152 (H) mm Industrial switches | | MBAK19004 | 19” Rack Mounting Kit for 74x105x152mm/74x135x152mm Industrial Switch |