BIDI SFP 1.25Gbps
1.25Gbps, WDM1310~1550, Single Fiber Bi-directional SFP, ONU Transceiver
- Distance: 10km, 20km, 40km, 60km, 80km
- Standard Operating Temperature: -10°C ~ 70°C
- Wide Operating Temperature: -40°C ~ 85°C
Lantech 1.25Gbps Bi-directional (BiDi) Small Form Factor Pluggable (SFP) transceiver module series is specifically designed for the high performance integrated duplex data link over a single optical fiber. These transceiver modules are compliant with the SFP Multisource Agreement (MSA). With the hot pluggability, these modules offer an easy way to be installed into SFP MSA compliant ports at any time without the interruption of the host equipments operating online.
Lantech 1.25Gbps BiDi SFP transceiver module series using a long wavelength DFB laser diode and enable data transmission up to 80km on a single-mode (9/125μm) optical fiber.
- 1.25G bi-directional single-fiber link
- Single LC receptacle
- 1310~1550nm FP/DFB transmitter
- 1310~1550nm PIN receiver
- 10km to 80km point-to-point transmission
- Compliant with IEEE802.3ah 1000Base-BX10-U Standard
- Compliant with SFF8472 diagnostic monitoring interface
- Compliant with SFP MSA
- Hot Pluggable
- RoHS Compliant
Specifications
Absolute Maximum Ratings
Recommended Operating Conditions
Transmitter Electro-Optical Characteristics
Receiver Electro-Optical Characteristics
Pin Assignment
Pin Description
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
As defined by the SFP MSA (SFF-8472) Lantech’s SFP transceivers provide digital diagnostic functions via a 2-wire serial interface, which allows real-time access to the following operating parameters:
- Transceiver temperature
- Laser bias current
- Transmitted optical power
- Received optical power
- Transceiver supply voltage
It also provides a sophisticated system of alarm and warning flags, which may be used to alert end-users when particular operating parameters are outside of a factory-set normal range.
The operating and diagnostics information is monitored and reported by a Digital Diagnostics Controller (DDC) inside the transceiver, which is accessed through the 2-wire serial interface. When the serial protocol is activated, the serial clock signal (SCL pin) is generated by the host. The positive edge clocks data into the SFP transceiver into those segments of its memory map that are not write-protected. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA pin) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially.
For more detailed information including memory map definitions, please see the SFP MSA (SFF-8472) Specification.
Digital Diagnostic Memory Map
|
Digital Diagnostic Monitoring Characteristics
Parameter |
Accuracy |
Unit |
Note |
Temperature |
±3 |
°C |
|
Supply Voltage |
±0.1 |
V |
|
TX Bias Current |
±5 |
mA |
|
TX Output Power |
±3 |
dB |
|
RX Received Optical Power |
±3 |
dB |
|
Part Number |
TX |
LD |
RX |
IO |
LOS |
Link |
Mode |
Temp. |
8330-197 |
1310nm |
FP |
1550nm |
AC/AC |
TTL |
0.5km |
Multi-mode |
-10~70°C |
8330-195 |
FP |
2km |
Single-mode |
|||||
8330-188 |
FP |
10km |
Single-mode |
|||||
8330-186 |
FP |
20km |
Single-mode |
|||||
8330-180 |
DFB |
40km |
Single-mode |
|||||
8330-181 |
DFB |
60km |
Single-mode |
|||||
8330-184 |
1490nm |
DFB |
80km |
Single-mode |
Part Number |
TX |
LD |
RX |
IO |
LOS |
Link |
Mode |
Temp. |
8330-197-E |
1310nm |
FP |
1550nm |
AC/AC |
TTL |
0.5km |
Multi-mode |
-40~85°C |
8330-195-E |
FP |
2km |
Single-mode |
|||||
8330-188-E |
FP |
10km |
Single-mode |
|||||
8330-186-E |
FP |
20km |
Single-mode |
|||||
8330-180-E |
DFB |
40km |
Single-mode |
|||||
8330-181-E |
DFB |
60km |
Single-mode |
|||||
8330-184-E |
1490nm |
DFB |
80km |
Single-mode |
Part Number |
TX |
LD |
RX |
IO |
LOS |
Link |
Mode |
Temp. |
8330-198 |
1550nm |
FP |
1310nm |
AC/AC |
TTL |
0.5km |
Multi-mode |
-10~70°C |
8330-196 |
2km |
Single-mode |
||||||
8330-189 |
DFB |
10km |
Single-mode |
|||||
8330-187 |
20km |
Single-mode |
||||||
8330-182 |
40km |
Single-mode |
||||||
8330-183 |
60km |
Single-mode |
||||||
8330-185 |
1490nm |
80km |
Single-mode |
Part Number |
TX |
LD |
RX |
IO |
LOS |
Link |
Mode |
Temp. |
8330-198-E |
1550nm |
FP |
1310nm |
AC/AC |
TTL |
0.5km |
Multi-mode |
-40~85°C |
8330-196-E |
2km |
Single-mode |
||||||
8330-189-E |
DFB |
10km |
Single-mode |
|||||
8330-187-E |
20km |
Single-mode |
||||||
8330-182-E |
40km |
Single-mode |
||||||
8330-183-E |
60km |
Single-mode |
||||||
8330-185-E |
1490nm |
80km |
Single-mode |