8 10/100TX + 4 10/100/1000T X-coded L2+ 8 PoE at/af EN50155 Managed Ethernet Switch w/ enhanced G.8032 Ring ; 24V/WV input models
- EN50155/61373/45545-2 verification; Compact size
- Built-in IEC 61375-3-4 ECN (Ethernet Consist Network) to work with IEC61375-2-5 ETBN
- IEEE802.3at/af up to 30W per port; PoE management incl. detection and scheduling
- Wide input range from 16.8V to 137.5V w/ galvanic isolation for IEEE802.3at/af max.80W power budget
- Galvanic isolation between input, PoE and output as well as case(WV model)
- Enhanced G.8032 ring protection < 20ms for single ring. Supports auto mode, enhanced mode, train mode, multi-VLAN and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 16MSTI /RSTP ; support MRP Ring
- Miss-wiring avoidance & node failure protection
- IP65/IP54 housing; User friendly UI, including auto topology drawing; Complete CLI
- Support LACP link aggregation, IGMP v3/router port, MLD snooping, DHCP server & DHCP Option82; DHCP Snooping, Port based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH v2/SSL, HTTPS, INGRESS/EGRESS ACL L2/L3,TACACS+**, QinQ
- Protocol based VLAN ; IPv4 Subnet based VLAN
- Optional bypass in case of power failure
- Environmental Monitoring for temp., voltage, current and total PoE load
- N-key configurator** for upgrading, auto back / editable configuration restore without computer
Lantech IPES-5408S (IP65/IP54) is a high performance L2+ (Gigabit uplink) switch with 8 10/100TX(D-coded) + 4 10/100/1000T(X-coded) w/8 PoE 802.3af/at ports by M12 provides L2 wire speed and advanced security function for network aggregation deployment. It delivers ITU G.8032 enhanced ring recovery less than 20ms in single ring while also supports train ring, enhanced mode, multiple VLAN mode with easy configuration. The comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, TACACS+**, SSH v2/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ are supported and also required in large network. It also supports Cisco Discovery Protocol (CDP) and Ciscoworks to detect the switch info and show on L2 map topology.
8x 802.3at/af ports w/advanced PoE management
Lantech IPES-5408S (IP65/IP54) supports IEEE802.3at/af standard which can feed HI-power up to 30W at each PoE port for big power consumption devices like PTZ IP camera, High power wireless AP etc. The advanced PoE management includes PoE detection and scheduling besides the regular PoE per port status. PoE detection can detect if the connected PD hangs then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Per port PoE status can remotely On/Off the power and display information of voltage, current, watt and PoE temperature.
Galvanic isolation for WV (16.8V~137.5VDC) input; 24V model ranging from 12V~56VDC input, High PoE budget
The Lantech IPES-5408S (IP65/IP54) provides galvanic isolation between DC input and PoE circuit for WV model. The WV model can accept dual power input (16.8V~137.5V) at PoE 80W budget. 24V model can work with dual input voltage from 12V~56VDC for PoE budget 90W. A voltage which can be minimal 0,5 Un nominal voltage (when Vin≧36V) and/or a voltage which can be maximal 1,5 Un nominal voltage for more than 1000 consecutive ms (one second).
Miss-wiring avoidance, Loop protection, Node failure protection
The IPES-5408S (IP65/IP54) also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech IPES-5408S (IP65/IP54) is able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
DHCP option 82 & Port based, Mac based DHCP, Option66, DHCP Snooping, IPv6 DHCP server
DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch) , it also can assign IP address by port for multiple switches with single DHCP option82 server. DHCP Snooping is supported. For the ending device which need to download file from TFTP server, DHCP Option66 server can offer IP address of TFTP server to DHCP client. Basic IPv6 DHCP service can be supported.
User friendly GUI, Auto topology drawing
The user friendly UI, innovative auto topology drawing and topology demo makes IPES-5408S (IP65/IP54) much easier to get hands-on. The complete CLI enables professional engineer to configure setting by command line.
Built-in IEC 61375-3-4 ECN (Ethernet Consist Network) to work with IEC61375-2-5 ETBN
Lantech OS1 Ethernet switches comply with IEC 61375-3-4 (ECN) standard. The support of Ethernet Consist Network allows interconnection between end devices located in single consist of train and interoperability with IEC61375-2-5 (ETBN).
Enhanced G.8032 ring, 16 MSTI MSTP; MRP Ring
Lantech IPES-5408S (IP65/IP54) features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over VLAN for redundant links with 16 MSTI.
MRP (Media Redundancy Protocol) can be supported for industrial automation networks.
Editable configuration file; Optional N-key auto backup, Exported text file
The configuration file of Lantech IPES-5408S (IP65/IP54) can be exported and edited with word processor for the other switches configuration with ease.
The optional N-key configurator offers mass firmware auto upgrade, auto back up /editable restoration by adjusting the DIP switch.
QoS by VLAN for legacy device
QoS by VLAN can allow switch to prioritize packets by VLAN tag regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.
QinQ, QoS and GVRP supported
It supports the QinQ, QoS, GVRP for large VLAN segmentation.
IGMPv3,GMRP, router port, MLD Snooping, static multicast forwarding and multicast Ring protection
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP, router port, MLD snooping and static multicast forwarding binding by ports for video surveillance application.
Event log & message; 2DI + 2DO
In case of event, the IPES-5408S (IP65/IP54) is able to send an email to pre-defined addresses as well as SNMP Traps out immediately. It provides 2DI and 2DO when disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.
Environmental monitoring for inside switch info
The built-in environmental monitoring can detect switch overall temperature, voltage, current and PoE total load where can send the SNMP traps, email** when abnormal.
EN50155, 45545-2, 50121-3-2, EN61373 verification; High ESD protection
Lantech IPES-5408S (IP65/IP54) features high reliability and robustness coping with extensive EMI/RFI phenomenon, environmental vibration and shocks usually found in factory, substation, steel automation, aviation, mining and process control. It is the best solution for Automation, transportation, surveillance, Wireless backhaul, Semi-conductor factory and assembly lines.
The IPES-5408S (IP65/IP54) is designed to meet with critical network environment with IP67/IP54 aluminum enclosure and M12 connectors for water proof. With EN45545-2 Fire & Smoke, and EN50155 & 61373 verification, the IPES-5408S (IP65/IP54) is best for railway in train/track side, vehicle and mining applications. For more usage flexibilities, IPES-5408S (IP65/IP54) supports wide operating temperature from -40°C to 75°C.
The IPES-5408S (IP65/IP54) also provides ±2000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet
Optional GigaT bypass
The optional bypass relay is set to bypass the switch to the next one when power is off in order to protect the network from crashing. Lantech bypass caters to remain in bypass mode until the switch is completely booting up when power is back to avoid another network lost. (-BT/-BBT model)