8 10/100/1000T X-coded EN50155 L2+ 8 PoE at/af Managed Ethernet Switch w/ Enhanced G.8032 Ring; WVI input
- EN50155/61373/45545-2 verification; 16.8~137.5V input
- Built-in IEC 61375-3-4 ECN (Ethernet Consist Network) to work with IEC61375-2-5 ETBN
- IEEE802.3at/af up to 30W per port; PoE budget up to 80W
- PoE management incl. detection and scheduling
- Galvanic isolation between input, PoE and output as well as case
- Enhanced G.8032 ring protection < 20ms for single ring. Supports auto mode, enhanced mode, train mode, multi-VLAN and basic mode; Enhanced G.8032 ring covers multicast packets; MSTP 16MSTI /RSTP; support MRP Ring
- IP54 Aluminum housing for best heat dissipation and preventing moist ingress
- Environmental Monitoring for temp., input voltage, current and total PoE load
- Miss-wiring avoidance & node failure protection
- Inrush current protection
- User friendly UI, including auto topology drawing; Complete CLI
- Support LACP link aggregation, IGMP v3/router port, MLD snooping, DHCP server & DHCP Option82; DHCP Snooping, Port based DHCP distribution, Mac based DHCP server, QoS by VLAN, SSH v2/SSL, HTTPS, INGRESS/EGRESS ACL L2/L3,TACACS+**, QinQ
- Protocol based VLAN; IPv4 Subnet based VLAN
- N-key configurator** for upgrading, auto back up /editable restoration without computer
Lantech TPGS-5008T (IP54) is a high performance L2+ All Gigabit Ethernet switch with 8 10/100/1000T w/8 PoE at/af ports up to 30W@ at M12 X-coded providing L2 wire speed and advanced security function for network aggregation deployment. It houses in an IP54 aluminum compact enclosure that is waterproof and will prevent moisture ingress due to temperature fluctuations. It delivers ITU G.8032 enhanced ring recovery less than 20ms in single ring while also supports train ring, enhanced mode, multiple VLAN mode with easy configuration. The comprehensive QoS, QoS by VLAN, advanced security including INGRESS/EGRESS ACL L2/L3, TACACS+**, SSH v2/SSL, Mac based DHCP server, DHCP Option 82, DHCP server, IGMPv1/v2/v3/router port, QinQ are supported and also required in large network. It also supports10K Jumbo frame.
Dual WVI (16.8V~137.5VDC) input, high PoE budget
WVI model w/PoE isolation accepts 16.8~137.5VDC dual input and can feed 54V output with max 80W PoE budget. A voltage which can be minimal 0,5 Un nominal voltage (when Vin≧36V) and/or a voltage which can be maximal 1,5 Un nominal voltage for more than 1000 consecutive ms (one second).
PoE +, Advanced PoE management
Lantech TPGS-5008T (IP54) supports IEEE802.3at/af standard which can feed power up to 30W at each PoE port for big power consumption devices like PTZ IP camera, wireless AP etc. The advanced PoE management includes PoE detection and scheduling besides the regular PoE per port status. PoE detection can detect if the connected PD is hang up then restart the PD; PoE scheduling is to allow pre-set power feeding schedule upon routine time table. Per port PoE status can remotely On/Off the power and display information of voltage, current, watt and PoE temperature.
Enhanced G.8032 ring, 16 MSTI MSTP; MRP Ring
Lantech TPGS-5008T (IP54) features enhanced G.8032 ring which can be self-healed in less than 20ms for single ring topology protection covering Multicast packets. It also supports various ring topologies that covers double ring, multi-chain (under enhanced ring), train ring, basic ring, multiple-VLAN ring and auto-ring by easy setup than others. The innovative auto-Ring configurator (auto mode) can calculate owner and neighbor in one step. It supports MSTP that allows RSTP over VLAN for redundant links with 16 MSTI. MRP (Media Redundancy Protocol) can be supported for industrial automation networks.
Miss-wiring avoidance, Loop protection, Node failure protection
The TPGS-5008T (IP54) also embedded several features for stronger and reliable network protection in an easy and intuitive way. When the pre-set ring configuration failed or looped by miss-wiring, Lantech TPGS-5008T (IP54) is able to alert with the LED indicator and disable ring automatically. Node failure protection ensures the switches in a ring to survive after power breakout is back. The status can be shown in NMS when each switch is back. This feature prevents the broken ring and keep ring alive without any re-configuration needed. Loop protection is also available to prevent the generation of broadcast storm when a dumb switch is inserted in a closed loop connection.
QoS by VLAN for legacy device
QoS by VLAN can allow switch to tag QoS by VLAN regardless the devices acknowledge QoS or not in which greatly enhance the bandwidth management in a network.
QinQ, QoS and GVRP supported
It supports the QinQ, QoS, GVRP for large VLAN segmentation.
IGMPv3,GMRP, router port, MLD Snooping, static multicast forwarding and multicast Ring protection
The unique multicast protection under enhanced G.8032 ring can offer immediate self-recovery instead of waiting for IGMP table timeout. It also supports IGMPv3, GMRP, router port, MLD snooping and static multicast forwarding binding by ports for video surveillance application.
Built-in IEC 61375-3-4 ECN (Ethernet Consist Network) to work with IEC61375-2-5 ETBN
Lantech OS1 Ethernet switches comply with IEC 61375-3-4 (ECN) standard. The support of Ethernet Consist Network allows interconnection between end devices located in single consist of train and interoperability with IEC61375-2-5 (ETBN).
DHCP option 82 & Port based, Mac based DHCP, Option66, DHCP Snooping, IPv6 DHCP server
DHCP server can assign dedicated IP address by MAC or by port (Port based for single switch) , it also can assign IP address by port for multiple switches with single DHCP option82 server. DHCP Snooping is supported. For the ending device which need to download file from TFTP server, DHCP Option66 server can offer IP address of TFTP server to DHCP client. Basic IPv6 DHCP service can be supported.
Auto-provisioning for firmware/configuration update
The switch supports auto-provisioning for switch to auto-check the latest software image and configuration through TFTP server.
User friendly GUI, Auto topology drawing
The user friendly UI, innovative auto topology drawing and topology demo makes TPGS-5008T (IP54) much easier to get hands-on. The complete CLI enables professional engineer to configure setting by command line.
Optional N key auto backup, exported text file
The configuration file of Lantech TPGS-5008T (IP54) can be exported in text file so that it can be edited and configured back to switch with ease for mass deployment. The optional N-key configurator offers firmware upgrade, auto backup/ editable configuration restore without computer by adjusting the DIP switch. The built-in watchdog design can automatically reboot the switch when CPU is found dead.
Event log & message; 2DI + 2DO
In case of event, the TPGS-5008T (IP54) is able to send an email** to pre-defined addresses as well as SNMP Traps out immediately. It provides 4DI and 3DO when disconnection of the specific port was detected; DO will activate the signal LED to alarm. DI can integrate the sensors for events and DO will trigger the alarm while sending alert information to IP network with email and traps.
Environmental monitoring for inside switch info
The built-in environmental monitoring can detect switch overall temperature, real input voltage, current and total PoE load where can send the SNMP traps and email** when abnormal.
High ESD protection, Inrush current protection
IPGS-5008T (IP54) provides ±2000V EFT and ±6000V ESD protection, which can reduce unstable situation caused by power line and Ethernet. The inrush current on initial power up can be limited lower than 10 x nominal current and for less than 1ms.
EN50155, EN45545-2, EN50121-3-2, EN61373 verification
The TPGS-5008T (IP54) passed serious tests under extensive Industrial EMI and Safety standards. With EN45545-2 Fire & Smoke, and EN50155 verification, the TPGS-5008T (IP54) is best for railway in train/track side, vehicle and mining applications. For more usage flexibilities, TPGS-5008T (IP54) supports wide operating temperature from -40°C to 75°C.